Twin solenoid in explosion-proof design. Thanks to the protection class-compliant flameproof housing, this product can be used worldwide – USA, RUS, IECEx, ATEX Approved for Division 1 plus Zone 1, 21 with gas and dust atmospheres. With its 39 x 25 mm valve interface and two independent coils, this twin model is ideal for very compact valve concepts.
This proportional solenoid is also available as a non-explosion-proof device.
Technical data | 24V | 12V |
---|---|---|
limit current [A] | 0.6 | 1.2 |
duty cycle [%] | 100 | 100 |
max. ambient temperature [C°] | +55 | +55 |
max. medium temperature [%] | +70 | +70 |
ingress protection rating | IP67 | IP67 |
thermal class (coil) | H | H |
static working pressure [bar] | 50 | 50 |
working stroke [mm] | 1.2 | 1.2 |
manual override | yes | yes |
surface treatment | iron parts zinc-plated EN 12329-Fe/Zn8/C or DIN 50979 Fe//ZnNi4-8//Cn//T0RoHS-conformed | iron parts zinc-plated EN 12329-Fe/Zn8/C or DIN 50979 Fe//ZnNi4-8//Cn//T0RoHS-conformed |
Type | Certification | Ambient temperature | Labeling |
---|---|---|---|
EX 04 | NEC 500 (USA) | -40 °C up to +55 °C | XP, Class I, Division 1, Group C, D, T4 DIP, Class II, Division 1, Group E, F, G, T4 DIP, Class III, Division 1 & 2 |
NEC 505 (USA) NEC 506 (USA) | -40 °C up to +55 °C | Class I, Zone 1, AEx d IIB, T4 Gb Zone 21, AEx tb IIIC T135 °C Db | |
CEC Section 18 Annex J | -40 °C up to +55 °C | XP, Class I, Division 1, Group C, D, T4 DIP, Class II, Division 1, Group E, F, G, T4 DIP, Class III, Division 1 & 2 | |
CEC Section 18 | -40 °C up to +55 °C | Class I, Zone 1, AEx d IIB, T4 Gb | |
ATEX | -40 °C up to +55 °C | II 2G Ex d IIB T4 Gb II 2D Ex tb IIIC T135 °C Db | |
IECEx | -40 °C up to +55 °C | Ex d IIB T4 Gb Ex tb IIIC T135 °C Db |